The following functions have been specified:
Amplification
Separation/combination of power supply and signal
The following environmental conditions have been specified:
Description: Minimum temperature
Value : -25
Units : Celsius
Test method: Climate chamber temperature setting
Description: Maximum temperature
Value : 70
Units : Celsius
Test method: Climate chamber temperature setting
The following cost factors have been specified:
Description: Maximum supply voltage
Value : 10
Units : V
Test method: Power supply setting during test
Description: Maximum power dissipation
Value : 0.25
Units : W
Test method: Measure current consumption from power supply and calculate the power
Description: PCA max length
Value : 50
Units : mm
Test method: Measure with ruler
Description: PCA max width
Value : 25
Units : mm
Test method: Measure with ruler
Description: PCA max height
Value : 15
Units : mm
Test method: Measure with ruler
Description: Antenna length
Value : 0.5
Units : m
Test method: Measure with ruler
The following performance requirements have been specified:
Description: Source impedance
Value : 6.427e-12
Units : F
Test method: Not tested
Description: Max. RMS value source voltage
Value : 0.225
Units : V
Test method: Setting test generator
Description: Min. -3dB signal frequency
Value : 100000
Units : Hz
Test method: Setting test generator
Description: Max. -3dB signal frequency
Value : 30000000
Units : Hz
Test method: Setting test generator
Description: Source-to-load voltage transfer
Value : 1
Units : -
Test method: Measure with network analyzer and capacitive source
Description: Output impedance
Value : 50
Units : Ohm
Test method: Measure with network analyzer
Description: Load impedance
Value : 50
Units : Ohm
Test method: Use 50 Ohm termination
Description: Source-referred noise spectrum floor
Value : 2.5e-17
Units : V^2/Hz
Test method: Spectrum analyser (with input amplifier) 50 Ohm termination
Description: Source-referred noise spectrum F^-2
Value : 1.0e-6/F^2
Units : V^2/Hz
Test method: Spectrum analyser (with input amplifier) 50 Ohm termination
Description: Peak-to-peak load voltage drive capability (at max current)
Value : 0.6364
Units : V
Test method: Oscilloscope, use 50 Ohm termination
Description: Peak-to-peak load current drive capability (at max voltage)
Value : 0.012728
Units : A
Test method: Oscilloscope, use 50 Ohm termination
Description: Load voltage slew rate
Value : 59978919.6651
Units : V/s
Test method: Oscilloscope, use 50 Ohm termination